Series KBF P | Constant climate chambers with ICH-compliant light source

Series KBF P | Constant climate chambers with ICH-compliant light source

Model

 
Housing dimensions not incl. fittings and connections
W x H x D
[mm]
Internal dimension 
W x H x D 
[mm]
Net weight 

[kg]
Interior volume 

[L]
KBF P 240 925 x 1460 x 800 650 x 785 x 485 213 247
KBF P 720 1250 x 1925 x 890 973 x 1250 x 576 374 700

KBF P 240 Constant climate chambers with ICH-compliant light source BINDER

Technical Data
Max. heat compensation at 40 °C with illumination [W] 1000
Temperature range with 100% illumination [°C] 10…60
Temperature range without illumination cassettes [°C] 0…70
Humidity fluctuation with illumination at 25 °C and 60 % RH [± % RH] 2
Humidity fluctuation with illumination at 40 °C and 75 % RH [± % RH] 2
Humidity range with illumination cassettes, with illumination [% RH] 10…75
Humidity range without illumination [% RH] 10…80
Humidty recovery time after 30 s door open at 25 °C and 60 % RH with illumination [min] 1
Humidty recovery time after 30 s door open at 40 °C and 75 % RH with illumination [min] 5
Temperature fluctuation with illumination at 25 °C and 60 % RH [± K] 0.2
Temperature fluctuation with illumination at 40 °C and 75 % RH [± K] 0.2
Temperature range with 100% illumination [°C] 20…60
Temperature range without illumination cassettes [°C] 10…70
Temperature variation with illumination at 25 °C and 60 % RH [± K] 1.2
Temperature variation with illumination at 40 °C and 75 % RH [± K] 1.2
ICH compliant illumination for photo stability testing [lx]* 9000
ICH compliant illumination for photo stability testing [W/m²]* 1.5
Nominal power [kW] 0
Phase (Nominal voltage) 1~
Power frequency [Hz] 50
Rated Voltage [V] 200…230
Unit fuse [A] 16
Inner doors 2
Unit doors 2
Depth [mm] 576
Height [mm] 1250
Width [mm] 973
Interior volume [L] 700
Load per rack [kg] 45
Net weight of the unit (empty) [kg] 374
permitted load [kg] 150
Depth net [mm] 890
Height net [mm] 1925
Wall clearance back [mm] 100
Wall clearance sidewise [mm] 200
Width net [mm] 1250
Energy consumption at 40 °C and 75 % RH [Wh/h] 2350
Sound-pressure level [dB(A)] 53
Number of illumination cassettes (std./max.) 3/3
Number of shelves (std./max.) 3/12
 

KBF P 240 Constant climate chambers with ICH-compliant light source BINDER

Technical Data
Max. heat compensation at 40 °C with illumination [W] 1000
Temperature range with 100% illumination [°C] 10…60
Temperature range without illumination cassettes [°C] 0…70
Humidity fluctuation with illumination at 25 °C and 60 % RH [± % RH] 2
Humidity fluctuation with illumination at 40 °C and 75 % RH [± % RH] 2
Humidity range with illumination cassettes, with illumination [% RH] 10…75
Humidity range without illumination [% RH] 10…80
Humidty recovery time after 30 s door open at 25 °C and 60 % RH with illumination [min] 4
Humidty recovery time after 30 s door open at 40 °C and 75 % RH with illumination [min] 5
Temperature fluctuation with illumination at 25 °C and 60 % RH [± K] 0.2
Temperature fluctuation with illumination at 40 °C and 75 % RH [± K] 0.2
Temperature range with 100% illumination [°C] 20…60
Temperature range without illumination cassettes [°C] 10…70
Temperature variation with illumination at 25 °C and 60 % RH [± K] 1.2
Temperature variation with illumination at 40 °C and 75 % RH [± K] 1.2
ICH compliant illumination for photo stability testing [lx]* 9000
ICH compliant illumination for photo stability testing [W/m²]* 1.5
Nominal power [kW] 3.5
Phase (Nominal voltage) 1~
Power frequency [Hz] 50/60
Rated Voltage [V] 200…230
Unit fuse [A] 16
Inner doors 2
Unit doors 2
Depth [mm] 576
Height [mm] 1250
Width [mm] 973
Interior volume [L] 700
Load per rack [kg] 45
Net weight of the unit (empty) [kg] 374
permitted load [kg] 150
Depth net [mm] 890
Height net [mm] 1925
Wall clearance back [mm] 100
Wall clearance sidewise [mm] 200
Width net [mm] 1250
Energy consumption at 40 °C and 75 % RH [Wh/h] 1850
Sound-pressure level [dB(A)] 53
Number of illumination cassettes (std./max.) 3/3
Number of shelves (std./max.) 3/12