Binder | Model CB-56 | CO₂ incubator
Binder
Model CB-56 | CO₂ incubator with hot air sterilization and heat sterilizable CO₂ sensor
Optimized humidification system with condensation protection
Tried-and-tested anti-contamination concept with 180 °C hot air sterilization
Hot-air sterilizable CO₂ sensor with single-beam infrared technology
Seamless inner chamber made of stainless steel
Fanless interior with flanges as shelf support system
Intuitive touchscreen controller with Venturi CO₂ gas mixing nozzle
Internal data recording can be read out in open format via USB interface
Fault diagnosis system with visual and acoustic alarm
Interfaces: Ethernet, USB, zero-voltage alarm contact
Fail-safe CO₂ system for protecting the pH of cell cultures
| Description | CB056-230V * | CB056-230V-O * | CB056UL-120V * | CB056UL-120V-O * |
| Article Number | 9640-0005 | 9640-0006 | 9640-0007 | 9640-0008 |
| Performance Data Temperature | ||||
| Temperature range +4 °C above ambient temperature to [°C] | 60 | 60 | ||
| Temperature range +5 °C above ambient temperature to [°C] | ||||
| Temperature range +6 °C above ambient temperature to | 60 °C | 60 °C | ||
| Temperature variation at 37 °C [± K] | 0.3 | 0.3 | 0.3 | 0.3 |
| Temperature fluctuation at 37 °C [± K] | 0.1 | 0.1 | 0.1 | 0.1 |
| Recovery time after 30 seconds door open at 37 °C [min] | 5 | 5 | 5 | 5 |
| Performance Data Climate | ||||
| Humidity range | 90…95 | 90…95 | 90…95 | 90…95 |
| CO₂-Data | ||||
| CO₂ range [Vol.-% CO₂] | 0…20 | 0…20 | 0…20 | 0…20 |
| CO₂ measurement | IR | IR | IR | IR |
| CO₂ Recovery time after 30 seconds door open at 5 Vol.-% CO₂ [min] | 5 | 5 | 5 | 5 |
| O₂-Data | ||||
| Standard O₂ control ranges: O₂ range [Vol.-% O₂] | 0.2…20 | 0.2…20 | ||
| O₂ control ranges with option: O₂ range [Vol.-% O₂] | 10…95 | 10…95 | ||
| O₂ Recovery time after 30 seconds door open at 5 Vol.-% O₂ [min] | 5 | 5 | ||
| O₂ Recovery time after 30 seconds door open at 10 Vol.-% O₂ [min] | 5 | 5 | ||
| Electrical data | ||||
| Rated Voltage [V] | 200…230 | 200…230 | 100…120 | 100…120 |
| Power frequency [Hz] | 50/60 | 50/60 | 50/60 | 50/60 |
| Nominal power [kW] | 0.8 | 0.8 | 0.8 | 0.8 |
| Unit fuse [A] | 10 | 10 | 16 | 16 |
| Phase (Nominal voltage) | 1~ | 1~ | 1~ | 1~ |
| Measures | ||||
| Interior volume [L] | 53 | 53 | 53 | 53 |
| Net weight of the unit (empty) [kg] | 53 | 53 | 53 | 53 |
| Permitted load [kg] | 30 | 30 | 30 | 30 |
| Load per rack [kg] | 10 | 10 | 10 | 10 |
| Wall clearance back [mm] | 100 | 100 | 100 | 100 |
| Wall clearance sidewise [mm] | 50 | 50 | 50 | 50 |
| Internal Dimensions | ||||
| Width [mm] | 400 | 400 | 400 | 400 |
| Height [mm] | 400 | 400 | 400 | 400 |
| Depth [mm] | 330 | 330 | 330 | 330 |
| Doors | ||||
| Inner doors | 1 | 1 | 1 | 1 |
| Unit doors | 1 | 1 | 1 | 1 |
| Housing dimensions not incl. fittings and connections | ||||
| Width net [mm] | 528 | 528 | 528 | 528 |
| Height net [mm] | 674 | 674 | 674 | 674 |
| Depth net [mm] | 545 | 545 | 545 | 545 |
| Environment-specific data | ||||
| Energy consumption at 37 °C [Wh/h] | 45 | 45 | 45 | 45 |
| Sound-pressure level [dB(A)] | 41 | 41 | 41 | 41 |
| Fixtures | ||||
| Number of shelves (std./max.) | 2/3 | 2/3 | 2/3 | 2/3 |